Table of figures, Precautions, Figure 1 - smt942 block diagram – Sundance SMT942 User Manual
Page 6: Figure 2 – setup packet structure, Figure 3 – control register read sequence
User Manual SMT942
Page 6 of 55
Last Edited: 23/08/2011 17:25:00
Table of Figures
SLB Base Module (In this case SMT351T)
SMT942 (SLB Mezzanine Module)
Virtex-5
XC5VLX50T, SX50T, SX95T, LX110T
FF1136 Package
Channel A
Signal
Conditioning
(AC-coupling)
Channel B
Signal
Conditioning
(AC-coupling)
DAC Output
Ch A MMCX
50-Ohm
DAC Output
Ch B MMCX
50-Ohm
Daughter Card
interface
connector
SLB
RSLA
ADC ChannelA and
ChannelB
RSLB
DAC ChannelA and
ChannelB
Top and Bottom TIM
Connectors
ChA Data (16)
and Control
Data and Clocks
4xComports (0,1,3 and 4)
DAC5688
Dual Channel DAC
16-bit 800MSPS
Interpolation
(1.3W)
Channel C
Signal
Conditioning
(AC-coupling)
Channel D
Signal
Conditioning
(AC-coupling)
DAC Output
Ch C MMCX
50-Ohm
DAC Output
Ch D MMCX
50-Ohm
DAC5688
Dual Channel DAC
16-bit 800MSPS
Interpolation
(1.3W)
Power
Daughter Card
connector
SLB
ChD Data (16)
and Control
ChC Data (16)
and Control
Bank A
2.5V
Bank B
2.5V
Bank C
2.5V
Power
Supplies: 1.8
and 3.3 Volts
(Linear
Regulators)
Power
Supplies: 1.0,
1.2, 1.8, 2.5
and 3.3 Volts
External Trigger
Clock Synchronizer
and Jitter Cleaner
based on
CDCE72010
(1.8W)
DACs External Clock In
- MMCX
External Reference
Clock In - MMCX
FPGA Clock
ChB Data (16) and
Control
DACs External Clock
Out - MMCX
Data and Clocks
Figure 1 - SMT942 Block diagram. ............................................................................... 10
Figure 2 – Setup Packet Structure. ....................................................................................... 12
Figure 3 – Control Register Read Sequence. ....................................................................... 13
Figure 4 – Register Memory Map. ......................................................................................... 14
Precautions
In order to guarantee that Sundance’s boards function correctly and to protect the
module from damage, the following precautions should be taken:
- They are static sensitive products and should be handled accordingly.
Always place the modules in a static protective bag during storage and transition.