1. To set the automatic measurement of start position using menu:
MSD-5404
Top
↓ SET key
[FUNCTION SELECT]
INPUT TIMING
▲▼keys: Select “INPUT TIMING”.
↓ SET key
[INPUT TIMING]
AUTO START POS
▲▼keys: Select “AUTO START POS”.
↓ SET key
[IN6 AUTO START]
O
N
▲▼keys: Select the desired mode (ALL OFF, OFF, ON).
◄►keys: Select the desired input (IN6 to IN9).
↓ ESC key: Returns to the previous screen.
2.
To set the automatic measurement of start position using commands:
@SIS: Set automatic measurement of start position
@GIS: Get automatic measurement of start position