Control software, Connection, Trans-scaler xt™ remote control” software – Analog Way Trans-Scaler XT - TSC550 User Manual
Page 18: Chapter 9 : control software
![background image](https://www.manualsdir.com/files/771860/content/doc018.png)
Chapter 9 : CONTROL SOFTWARE TRANS-SCALER XT™
PAGE 18
Chapter 9 : CONTROL SOFTWARE
9-1. CONNECTION
• CONNECTING THE RS-232
Connect the serial port of your control device to the REMOTE CONTROL (RS-232) connector (DB9 Female) of the
TRANS-SCALER XT
™
with the a straight cable (DB9 female / DB9 male).
• PIN-OUT
PIN #
FUNCTIONS
2
TRANSMIT DATA (Tx).
3
RECEIVE DATA (Rx).
5
GROUND (Gnd).
DB9 female connector.
(Rear panel of the TRANS-SCALER XT
™
).
• SPEED TRANSMISSION : 9600 bauds, 8 data bits, 1 stop bit, no parity bit, no flow control.
9-2. “TRANS-SCALER XT
™
REMOTE CONTROL” SOFTWARE
Your TRANS-SCALER XT
™
is shipped with a WINDOWS 95/98/2000/Me/XP compatible "TRANS-SCALER XT
™
REMOTE CONTROL" software (3.5" disk). This software allows you to control and make adjustments to the TSC550 by a
simple mouse click (output format, image adjustments, etc...).
• SOFTWARE INSTALLATION:
c Turn ON your computer and wait for WINDOWS to completely start.
d Insert the disk into the floppy drive.
e In the WINDOWS START menu, click on RUN.
f Choose the disk drive and click on setup.exe (ex : A:\setup.exe if the 3.5” disk is drive A).
g Follow the WINDOWS installation instructions: WINDOWS will create a file C:\Program files \ ANALOGWAY \
Trans-scaler XT Remote Control.
• STARTING UP:
c Connect the RS-232 cables between the control device and the TRANS-SCALER XT
™
as indicated in section 9-1.
d Then power ON all of the devices.
e Click on the programs file TSC550 in Start-Program-ANALOG WAY to run the software.
f Click on the Controls menu and select the Serial port.
The TRANS-SCALER XT
™
is now connected to the computer (if not, verify the DB9 serial connection and the selected
serial port).