B. ground-level installation, C. clearances – Bryant 542E User Manual
Page 2
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

542E REQUIRED CLEARANCE (Inches)
Top of unit ............................... 48 Blower access door end..
Duct side of unit...................... 12 End opposite blower
Compressor access door access end
side........ ............................. 30 Bottom of unit above
..30
.112
■ anticipated snow level.. ■6
i-E
. CONTROL ACCESS DOOR^ 7
\ /-4
oia
r-i DIÁ
HIGH-VOLTAGE
.«------------------
A
COMPRESSOR
ACCESS DOOR
INLET WITH MULTIPLE.
KNOCKOUTS
U-N"
“T
M
_L
-SUPPLY-AIR
,MPT
DRAIN
^CONNECTION
ELECTRIC HEAT
HIGH-VOLTAGE INLET WITH
MULTIPLE KNOCKOUTS
A79071
542E DIMENSIONS (Inches)
Size
A
B
c
D
E
F
G
H
J
024 & 030
60-3/16
32-3/16
24-13/16
21
11-1/2
13-5/16
54
6-7/8
6-15/16
036
60-3/16
32-3/16
24-13/16
21
13-3/4
13-5/16
54
4-5/8
6-15/16
042, 048, & 060
68-3/16
40-3/16
30-13/16
21
16-3/8
17-5/16
61-3/16
5-1/8
' 7-1/2
Sizes
K
L
M
N
P
R
S
T
U
V
024 & 030
18-1/8
3
15-3/32
12-9/16
13
,28-9/16
37-1/8
2
7/8
27-3/8
036
18-1/8
3
15-3/32
12-9/16
13
28-9/16
37-1/8
2
7/8
27-3/8
042, 048, & 060
25
3-3/8
20-3/32
15-1/8
16-19/32
34-9/16
44-1/4
2
7/8
33-11/16
Figure 3--542E Dimensional Drawing
TABLE l-RATINGS, PERFORMANCE, & RECOMMENDED FILTER SIZES
MODEL
542E
542D
SIZE
024
030
036
042
048
060
060
SERIES
A
A
A
A
A
A
A
Rated Heating Capacity® 47°F (Btuh)*
26,000
30,000
35,000
43,000
48,000
58,000
58,000
Total Power Consumption (Watts)*
2850
3300
3850
4700
5100
6300
6300
COP*
2.7
2.7
2.7
2.7
2.8
2.7
2.7
Rated Heating Capacity® 17°F (Btuh)*
14,000
16,000
18,000
22,000
25,000
31,500
31,500
Total Power Consumption (Watts)*
2300
2650
3000
3650
4150
5200
5200
COP*
1.8
1.8
1.8
1.8
1,8
1.8
1.8
Rated Cooling Capacity @ 95°F (Btuh)*
25,500
30,000
35,000
43,000
47,000
58,000
58,000
Total Power Consumption (Watts)*
3350
3800
4650
5300
6100
7700
7700
EER
7.6
7.9
7.5
8.1
7.7
7.5
7.5
Rated Indoor Airflow (Ft3/Min)*
850
1050
1300
1550
1700
2000
2000
Rated External Static Pressure (In. wc)*
0.3
0.3
0.3
0.3
0.3
0.3
0.3
ARI Sound Rating Humbert
19
19
19
18
18
20
20
Recommended Minimum Filter Size (Sq ln.)t
Standard-Type
408
504
624
744
816
960
**
Cleanable- or High-Capacity-Type
265
328
406
484
530
624
**
* Rated in accordance with ARI Standard 240-77.
t
Rated in accordance with ARI Standard 270-75.
i Recommended field-supplied filter sizes shown are
**Two 20
X
20
X
2 high-capacity filters are furnished
based on a velocity of 300 ft/min at the rated indoor airfow.
with Model 542D060.
plenum, the accessory roof mounting curb must be installed
on and flashed into the roof before unit installation. The in
structions for installing the curb are packaged with the
curb.
CAUTION:
Be sure that the roof will support the additional
weight. Refer to Figure 5 or 6 for weight information. On a
downflow installation with a-Model 542D or a Model 542E
with an accessory downflow plenum where the accessory roof
mounting curb is not being used, the field-fabricated support
must be level and must properly support the unit and down-
flow plenum.
When installing a Model 542E without an accessory down
flow plenum, place the unit on a level base that provides
proper support. On flat roofs, be sure that the unit is at least
4 inches above the highest expected water level on the roof
to prevent flooding. Consult local codes for installation re
quirements.
NOTE:
See Figure 10 for a typical rooftop installation.
B. Ground-Level Installation
The unit must be placed on a solid level concrete pad that is
a minimum of 4 inches thick and that extends approximate
ly 2 inches beyond the casing on all four sides of the unit.
The unit does not need to be secured to the pad except when
required by local codes.
NOTE:
See Figure 11 for a typical ground level installation.
C. Clearances
The required minimum operating and service clearances are
-
2
-