9.
Cut out a 10” X 12” square of insulation on the firewall behind the stock turbo.
Install a piece if high temp heat shield supplied in its place.
11.
Install turbo support bracket on passenger side of motor using supplied bolts. Remove stock bolts
connecting grounds bolt bracket and connect grounds. (Note: 2 upper bolts LBZ, 2 lower bolts LMM
(Note: move all hoses and, wires, Air conditioning tubes out of the way.)
10.
Install new supplied up pipe and gaskets using factory bolts.
LBZ
LMM
REINSTALL GROUND
WIRES
NEW HEAT SHIELD
INSTALLED