beautypg.com

Nspections and, Esting, Every-lift inspection – Wood’s Powr-Grip CB1 User Manual

Page 9: Frequent inspection, Periodic inspection, Infrequent use, Maintenance

background image

Rev 1.0/6-13

7

CB1: #35168

MAINTENANCE

I

NSPECTIONS AND

T

ESTING

When performing inspections and tests of the P2 Channel Lifter as directed in the MAINTENANCE

section of the lifter's instruction manual, be sure to include the Counter-Balancer whenever
applicable. Consult the following topics for additional directions.

Every-Lift Inspection:

• Examine the lift shackles and shackle pins for signs of wear or damage.
• Examine the lift slings for fraying or other signs of wear or damage.
• Be sure all fasteners are secure before use.
If any deficiency is detected during the inspection, correct it before using the Counter-Balancer

and perform the Frequent Inspection to follow.

Frequent Inspection:

• Examine all fasteners for signs of wear or damage.
• Be sure all fasteners are secure before use.
• Examine the Counter-Balancer’s structure for visual damage.
If any deficiency is detected during the inspection, correct it before using the Counter-Balancer

and perform the Periodic Inspection to follow.

Periodic Inspection:

• Examine the entire Counter-Balancer for external evidence of looseness, excessive wear,

deformation, cracks, excessive corrosion, dents to structural or functional components, cuts,
or any deficiency which might constitute a hazard.

• Keep a written record of all Periodic Inspections.
If any deficiency is detected during the inspection, return the Counter-Balancer to Wood’s Powr-

Grip or an authorized dealer for repair (see LIMITED WARRANTY).

Infrequent Use

If the Counter-Balancer is used less than 1 day in a 2-week period, perform the Periodic

Inspection

each time before using the Counter-Balancer

.