4 preset commands, 1 operation commands – Kramer Electronics VS-88FO User Manual
Page 37
34
VS-88FO - Kramer Protocol 3000
9.3.4
Preset Commands
Command
Syntax
Response
Store current connections to
preset
PRST-STO PRESET
Short form: PSTO PRESET
PRST-STO PRESET RESULT
Recall saved preset
PRST-RCL PRESET
Short form: PRCL PRESET
PRST-RCL PRESET RESULT
Delete saved preset
PRST-DEL PRESET
Short form: PDEL PRESET
PRST-DEL PRESET RESULT
Read video connections from
saved preset
PRST-VID? PRESET,OUT
Short form: PVID? PRESET,OUT
PRST-VID? PRESET, *
PRST-VID PRESET, IN>OUT
PRST-VID PRESET, IN>1, IN
>2,…
Read saved presets list
PRST-LST?
Short form: PLST?
PRST-LST PRESET, PRESET
, …
Parameter Description:
PRESET = Preset number.
OUT = Output in preset to display, '*' for all.
Examples:
Store current video connections
to preset 5
#PRST-STO 5CR
~PRST-STR 5 OKCRLF
Recall video connections from
preset 3
#PRCL 3CR
~PRST-RCL 3 OKCRLF
Show source of video output 2
from preset 3
#PRST-VID? 3,2CR
~PRST-VID 3: 4>2 CRLF
9.3.1
Operation Commands
Command
Syntax
Response
Set genlock
#GNLCK out,in,type CR
~ nn@GNLCK out,in,status CRLF
Get genlock
#GNLCK? out CR
~ nn@GNLCK out,in,status CRLF
Parameter Description:
out- output number (1 .. max number of outputs)
in
– input number (1… max number of inputs)
type
– genlock type
3
1080@60
4
1080@50
5
720@60
6
PAL
7
NTSC
status
– genlock status (ON/OFF)
Lock front panel
LOCK-FP LOCK-MODE
Short form: LCK LOCK-MODE
LOCK-FP LOCK-MODE RESULT
Get front panel locking state
LOCK-FP?
LOCK-FP LOCK-MODE
Parameter Description:
LOCK-MODE = Front panel locking state:
‘0’ or ‘off’ to unlock front panel buttons
‘1’ or ‘on’ to lock front panel buttons
Reset device
RESET
RESET OK
Switch to protocol 2000*
P2000
P2000 OK
* Protocol 2000 has a command to switch back to ASCII protocol (like Protocol 3000)