Pump timer settings for sanitizer tank ( kayquat ) – Power Soak 27173 Chemical Dispenser Installation Guide User Manual
Page 6

6
Pump Timer Settings for Sanitizer Tank (
Kayquat
)
Open the dual dispenser pump enclosure and locate the correct timer for the
Kayquat (sanitizer) dispenser pump. The correct timer is mounted on the
right-hand
side of the door. The DIP switches on the timer represent a spe-
cific number of seconds. Set any combination of the switches to “ON” in or-
der to obtain the proper amount of pump run time.
To determine the correct timer setting, measure the depth of the Power Soak
unit (from the front edge to the back edge). Then, measure the Sanitizer
Tank from the left side to the right side. Use the following information to set
the DIP switches on the timer:
34" deep unit
- Kayquat Timer Settings for PS-200 Sanitizer Tank
Tank
Length
(inches)
Tank
Volume
(gallons)
Kayquat
(ounces)
Pump
Time
(seconds)
DIP Switch Settings
(ON)
14
20.9
5.52
44
32, 8, 4
16
23.9
6.31
50
32, 16, 2
19
28.4
7.49
60
32, 16, 8, 4
20
29.9
7.89
63
32, 16, 8, 4, 2, 1
24
35.8
9.46
76
64, 8, 4
30
44.8
11.83
95
64, 16, 8, 4, 2, 1
30" deep unit
- Kayquat Timer Settings for PS-200 Sanitizer Tank
Tank
Length
(inches)
Tank
Volume
(gallons)
Kayquat
(ounces)
Pump
Time
(seconds)
DIP Switch Settings
(ON)
14
18.0
4.75
38
32, 4, 2
16
20.6
5.43
43
32, 8, 2, 1
19
24.4
6.45
52
32, 16, 4
20
25.7
6.79
54
32, 16, 4, 2
24 30.9 8.15 65
64,
1
30
38.6
10.18
81
64, 16, 1