To determine the correct timer setting, measure the depth of the Power Soak
unit (from the front edge to the back edge). Then, measure the Wash Tank
from the left side to the right side. Use the following information to set the
DIP switches on the timer:
34" deep unit
- Liquid Storm Timer Settings for PS-200 Wash Tank
Tank
Length
(inches)
Tank
Volume
(gallons)
Liquid
Storm
(ounces)
Pump
Time
(seconds)
DIP Switch Settings
(ON)
30
59.7
5.74
69
64, 4, 1
36
71.7
6.88
83
64, 16, 2, 1
42
83.6
8.03
96
64, 32, 1
48
95.6
9.18
110
64, 32, 8, 4, 2, 1
54
107.5
10.32
124
64, 32, 16, 8, 4
60
119.5
11.47
138
128, 8, 1
66
131.4
12.62
151
128, 16, 4, 2, 1
72
143.4
13.76
165
128, 32, 4, 1
Pump Timer Settings for Wash Tank (
Liquid Storm
),
cont’d
30" deep unit
- Liquid Storm Timer Settings for PS-200 Wash Tank
Tank
Length
(inches)
Tank
Volume
(gallons)
Liquid
Storm
(ounces)
Pump
Time
(seconds)
DIP Switch Settings
(ON)
30
51.4
4.94
59
32, 16, 8, 2, 1
36
61.7
5.92
71
64, 4, 2, 1
42
72.0
6.91
83
64, 16, 2, 1
48
82.3
7.90
95
64, 16, 8, 4, 2, 1
54
92.6
8.89
107
64, 32, 8, 2, 1
60
102.9
9.87
118
64, 32, 16, 4, 2
66 113.1
10.86 130
128,
2
72
123.4
11.85
142
128, 8, 4, 2