To determine the correct timer setting, measure the depth of the Power Soak
unit (from the front edge to the back edge). Then, measure the Wash Tank

from the left side to the right side. Use the following information to set the
DIP switches on the timer:

34" deep unit

- Liquid Storm Timer Settings for PS-200 Wash Tank

Tank

Length

(inches)

Tank

Volume

(gallons)

Liquid

Storm

(ounces)

Pump

Time

(seconds)

DIP Switch Settings

(ON)

30

59.7

5.74

69

64, 4, 1

36

71.7

6.88

83

64, 16, 2, 1

42

83.6

8.03

96

64, 32, 1

48

95.6

9.18

110

64, 32, 8, 4, 2, 1

54

107.5

10.32

124

64, 32, 16, 8, 4

60

119.5

11.47

138

128, 8, 1

66

131.4

12.62

151

128, 16, 4, 2, 1

72

143.4

13.76

165

128, 32, 4, 1

Pump Timer Settings for Wash Tank (

Liquid Storm

),

cont’d

30" deep unit

- Liquid Storm Timer Settings for PS-200 Wash Tank

Tank

Length

(inches)

Tank

Volume

(gallons)

Liquid

Storm

(ounces)

Pump

Time

(seconds)

DIP Switch Settings

(ON)

30

51.4

4.94

59

32, 16, 8, 2, 1

36

61.7

5.92

71

64, 4, 2, 1

42

72.0

6.91

83

64, 16, 2, 1

48

82.3

7.90

95

64, 16, 8, 4, 2, 1

54

92.6

8.89

107

64, 32, 8, 2, 1

60

102.9

9.87

118

64, 32, 16, 4, 2

66 113.1

10.86 130

128,

2

72

123.4

11.85

142

128, 8, 4, 2