beautypg.com

Pump timer settings for wash tank ( liquid storm ) – Power Soak 27173 Chemical Dispenser Installation Guide User Manual

Page 4

background image

4

Step #5

Place a bag of Liquid Storm detergent into the bag
holder. Locate the detergent connector fitting,

fasten it to the Feed Tube then connect the fitting
to the bag of Liquid Storm.

Warning: Refer to, and follow, all specific handling

instructions provided by the chemical manufac-
turer. Instructions, labels and MSDS sheets

should be supplied with the detergent.

Step #6
Connect the Feed Tube from the Sanitizer pump to

the Kayquat sanitizer supply.

Warning: Refer to, and follow, all specific handling

instructions provided by the chemical manufac-
turer. Instructions, labels and MSDS sheets

should be supplied with the sanitizing agent.

Pump Timer Settings for Wash Tank (

Liquid Storm

)

Open the dual dispenser pump enclosure and locate the correct timer for the
Liquid Storm (detergent) dispenser pump. The correct timer is mounted on

the

left-hand

side of the door. The DIP switches on the timer represent a

specific number of seconds. Set any combination of the switches to “ON” in

order to obtain the proper amount of pump run time.

DIP switches for

DETERGENT

pump timer

DIP switches for

SANITIZER

pump timer