Regen, Time, Gallons – Hellenbrand H-125 Series User Manual

Page 11

background image

11

STEP 12 S – Set Regeneration Time Options using the  or  button. If value is set to:

• “DELAY” means regeneration will occur at the preset time; (page 8, step 4)

• “IMMEDIATE” means regeneration will occur immediately when the gallons capacity reaches 0

(zero); or

• “DELAY + IMMEDIATE” means regeneration will occur at one of the following:

- the preset time when the gallons capacity falls below the reserve or the specified number of days

between regenerations is reached, whichever comes first; or

- immediately after 10 minutes of no water usage when the gallon capacity reaches 0 (zero).

See page 34 for more options. Factory Setting is DELAY + IMMEDIATE. Press NEXT to go to

Step 13S. Press REGEN to return to previous step.

STEP 13 S – Set Relay to activate by Time or Gallons, REGEN GALLONS or OFF by using 

or  buttons. A relay can be used to operate a chemical feed pump or solenoid. The choices are:

• Relay Triggered on Time - Relay activates after set number of minutes after start of regenera-

tion. Start of regeneration is defined by first backwash cycle, dn brine or up brine, whichever

is first. Relay deactivates after set time.

• Relay Triggered on Gallons - Relay activates every set number of gallons while in service and

deactivates after set time.

• Regen Gallons - Relay activates after set number of gallons in service and if any water is

used during regeneration and de-activates after set time or when meter stops registering flow,

whichever comes first.

Off - If off is selected, Steps 14S or 15S will not be shown. Factory setting = OFF. Press

NEXT to go to step 14S or 15S for relay settings, or 20S if OFF selected.

STEP 14 S – If off was selected in previous step, this screen does not appear.

If Time chosen to Activate Relay, use up and down arrows to set # of minutes AFTER START OF

REGEN to activate relay. Press NEXT.

Start of regeneration is defined as first Backwash or Regenerant Draw.

STEP 15 S – Use Up and Down arrows to set duration of relay activation in minutes.

Time Range = 1 second - 500 minutes. Press NEXT to go to Step 20S. Press REGEN to return to

previous step.

Gallons Chosen to Activate Relay, This screen indicated gallons chosen to activate relay. If Off

or Time was selected in previous steps, this screen does not appear. Press NEXT to select number

of gallons per relay activation.

STEP 16 S – use up and down arrows to set # of gallons per relay activation.

Range = 1-100 gallons. Press NEXT to select duration of relay activation.

STEP 17 S – Use up and down arrows to set duration of relay activation in minutes. Range = 1

second - 500 minutes. Press NEXT to go to Step 20S. Press REGEN to return to previous step.

Figure 12b

RELAY 1 DURATION

Step 12S

DELAY + IMMEDIATE

REGEN

Step 13S

RELAY 1 TRIGGER

TIME

Step 14S

RELAY 1 SET POINT

10

MIN

RELAY 1 DURATION

3:00

MIN

Step 15S

RELAY 1 TRIGGER

GALLONS

RELAY 1 SETPOINT

GAL

1

SET

SET

SET

SET

SET

SET

SET

0:01

MIN

Step 16S

Step 17S