Installation, Steamer connections, Flush mount – AccuTemp EVOLUTION GAS STEAMER User Manual
Page 12: Connected connectionless

MP4010-1003
EVOLUTION GAS STEAMER
6
STEAMER CONNECTIONS
The Evolution Gas Steamer is available in a connected and connection less models.
Both the connection-less and connected model will require a gas connection and a electrical
connection.
INSTALLATION
To Flush mount the appliance to a counter to:,
Drill 4 holes per above drawing.
1.
Attach the appliance to counter top with (4) 1/4-20 x 3/4” hex head bolts and 1/4-20 split lock
2.
washers.
Apply a bead of high temp food grade silicone caulking around the perimeter and smooth out.
3.
FLUSH MOUNT
This model must be manually filled with tap water and must be filled throughout the cooking process
to assure consistent cook times. Do not use the “Low Water Indicator” as your indication that this
steamer requires water as this actually turns off the heat to the product thus stopping the cooking
process. A full size steam table pan or a 1/1 gastronome pan must installed in rails under the steamer
any time the steamer is operating and anytime that the steamer is being cleaned or drained of the
water in the cooking chamber. Failure to follow this directions will cause a the steamer to fail which is
not covered under the limited warranty. See Fig. 4
The connected model in addition to the gas and electrical connection will require a water connection
and access to a floor drain or sink to route a drain hose (not supplied) to allow condensate to be
removed and to drain the steamer when required.
See Fig. for identifications of the required steamer connections. See Fig. 3
CONNECTED
CONNECTIONLESS
Fig.2