Table 10
The RS-232 19-character Fixed Length Output
Message
Character
position
Message
1 “
☻” 02H (
2 “W”
3
“5” for 5-second running average
4
“P” for “pass”
“F” for “fail”
5
Wind direction (most significant digit)
6
Wind direction (middle digit)
7
Wind direction (least significant digit)
8
Wind speed (most significant digit)
9
Wind speed (next digit)
10
Wind speed (next digit)
11
Wind speed (least significant digit)
12
“.” (dot character)
13
Wind speed (tenth digit)
14
“M” for miles per hour; “K” for knots
“L” for kilometers per hour; “T” for meters per second
15
Check sum (most significant digit) (See note)
16
Check sum (least significant digit)
17 “
♥” 03H (
18
[CR] (carriage return)
19
[LF] (line feed)
NOTE
The checksum is calculated from 13 characters from position 2 through
14. The accumulator initializes at 0 with the addition of the byte value.
The checksum has a range of 0H … FFH.
Missing Readings
If data is missing due to a measurement problem, Handar RS-232
message reports 999.9 for wind speed.
NOTE
The sensor has a 20 ms timeout in receiving characters. Therefore,
polling strings should be transmitted by a programmable device, not as a
user command via terminal sessions.