background image

Chapter 4 ________________________________________________________________ Operation

VAISALA _______________________________________________________________________ 39

Serial Mode Default Settings for Europe

Operation Mode:

NMEA Extended

Wind Speed Units:

Meters/Second

Average Interval (seconds):

3

Averaging Method:

Scalar

Output Interval (seconds, 0 for polled):

1

Sensor ID Character:

A

Wind Direction Coast Threshold (speed units): 0.0
Head Orientation:

Up

Baud Rate:

9600b

Parity: None
Data Bits:

8

NOTE

These default settings for Europe are used for product ordering options
x2xxx (for example, WS425 A2A1A, where the number 2 refers to the
default settings).

Configuration Menu

The configuration menu can be opened by typing

Open

or

Open

where

is the identification character of the sensor.

If the sensor has been running for more than five seconds, use the
currently active baud rate and other communication settings. There is a
short timeout in typing in the characters. Therefore, type the OPEN
command followed by ENTER relatively fast.

The OPEN command displays the following menu (on the next page):