Serial mode default settings for europe, Configuration menu – Vaisala WS425 User Manual
Page 39
Chapter 4 ________________________________________________________________ Operation
VAISALA _______________________________________________________________________ 39
Serial Mode Default Settings for Europe
Operation Mode:
NMEA Extended
Wind Speed Units:
Meters/Second
Average Interval (seconds):
3
Averaging Method:
Scalar
Output Interval (seconds, 0 for polled):
1
Sensor ID Character:
A
Wind Direction Coast Threshold (speed units): 0.0
Head Orientation:
Up
Baud Rate:
9600b
Parity: None
Data Bits:
8
NOTE
These default settings for Europe are used for product ordering options
x2xxx (for example, WS425 A2A1A, where the number 2 refers to the
default settings).
Configuration Menu
The configuration menu can be opened by typing
Open
or
Open
where
is the identification character of the sensor.
If the sensor has been running for more than five seconds, use the
currently active baud rate and other communication settings. There is a
short timeout in typing in the characters. Therefore, type the OPEN
command followed by ENTER relatively fast.
The OPEN command displays the following menu (on the next page):