beautypg.com

AVE MV DR4000 User Manual

Page 48

background image

46

6. RS-232 & RS-485 Protocol

6.1 Setup

6.1.1

Use a Null Modem cable (the standard RS-232 9 Pin Cable with Pin 2 and Pin 3 exchanged, see pin

configuration chart below for details) to connect the COM 1 on the rear panel of the DVR to a PC.

6.1.2

Set the

RS-232

option to

ON

in the

COMMUNICATION

page of the setup menu.

6.1.3

Set the PC communication parameters: 9600 bps, No Parity, 8 Data Bits, 1 Stop Bit.

6.2 Communication Protocol

6.2.0 General Command Format

, < Dest ID >, < Src ID >,

, , {parameters>, , ..,}

Lead Code = 0x41

Dest ID = 0x01
Src ID = 0x20

Main Category = 0x01

Keys and Signals

= 0x02 Command

Second Category = 0x01 Handshake

= 0x02 Request Time/Set Time

= 0x06 Request System State

= 0x0b Time Search

= 0x10 Request HDD Info

= 0x11 Request REC Position

= 0x12 Playback Immediately

End Code= 0x4f

The different command types and their corresponding parameters are as follows:

6.2.1 Keys and signals

PC Send: <0x41>, <0x01>, <0x20>, <0x01>, , <0x4f>