beautypg.com

Electronic functional description – Amana Bottom Mount Refrigerator User Manual

Page 32

background image

RS1200001

32

November 1996

Electronic Functional Description

Refrigeration and Defrost Component Checks Made at High Voltage Board

Low voltage board input

W1 to D11

approximately

-25 VDC

High voltage board input

E10 to E9 (Neutral) or ground

approximately

120 VAC

Compressor/condenser fan motor

“ON” = E4 to E9 (Neutral) ground

approximately

120 VAC

“OFF” = E4 to E9 (Neutral) or ground

Compressor/condenser fan motor

“CLOSED” = R7 to ground

approximately

-11 VDC

relay“OPEN” = R7 to ground

approximately

-25 VDC

Evaporator fan motor relay

“CLOSED” = R8 to ground

approximately

-11 VDC

“OPEN” = R8 to ground

-25 VDC

Evaporator fan motor

“ON” = E2 to E9 (Neutral) or ground

approximately

120 VAC

“OFF” = E2 to E9 (Neutral) or ground

0 VAC

Defrost heater

“ON” = E6 to E9 (Neutral) or ground

approximately

120 VAC

“OFF” = E6 to E9 (Neutral) or ground

0 VAC

Defrost heater relay

“CLOSED” = R9 to ground

approximately

-11 VDC

“OPEN” = R9 to ground

approximately

-25 VDC

Defrost terminator

“CLOSED” = E5 to E9 (Neutral) or ground

approximately

120 VAC

“OPEN” = E5 to E9 (Neutral) or ground

0 VAC

Fresh food fan output voltage

“ON” = E1 to ground

approximately

-25 VDC

High voltage board to fresh food fan

“OFF” = E1 to ground

0 VDC

Fresh food fan input voltage

“ON” = R10 to ground

approximately

-11 VDC

Signal to high voltage board from
low voltage board

“OFF” = R10 to ground

approximately

-25 VDC

Filament voltage at pins 11 and 12 = less than 5 VAC

To avoid electrical shock which can cause severe personal injury or death, disconnect power to
refrigerator using power switch before servicing. Wires removed during disassembly must be replaced on
proper terminals to insure correct earthing and polarization. After servicing, reconnect power using power
switch.

WARNING