beautypg.com

Hfc134a service information – Amana Bottom Mount Refrigerator User Manual

Page 14

background image

RS1200001

14

November 1996

Service Equipment

Listed below is equipment needed for proper
servicing of HFC134a systems. Verify equipment is
confirmed by manufacturer as being compatible with
HFC134a and ester oil system.

Equipment must be exclusively used for HFC134a.
Exclusive use of equipment only applies to italic
items.

Evacuation pump

Check with vacuum pump supplier to verify
equipment is compatible for HFC134a. Robinair,
Model 15600, 2 stage, 6 cubic feet per minute pump
is recommended.

Four-way manifold gauge set, with low loss hoses
Leak detector
Charging cylinder
Line piercing saddle valve

(Schroeder valves). Seals must be HFC134a and
ester oil compatible. Line piercing valves may be used
for diagnosis but are not suitable for evacuation or
charging, due to minute holes pierced in tubing. Do
not leave mechanical access valves on system.
Valves eventually will leak. Molecules of HFC134a are
smaller than other refrigerants and will leak where
other refrigerants would not.

Swaging tools
Flaring tools
Tubing cutter
Flux
Sil-Fos
Silver solder
Oil for swaging and flaring

Use only part #R0157532

Copper tubing

Use only part #R0174075 and #R0174076

Dry nitrogen

99.5% minimum purity, with -40°F or lower dew point

Crimp tool
Tube bender
Micron vacuum gauge
Process tube adaptor kit
Heat trap paste
ICI appliance grade HFC134a

Drier Replacement

Prior to opening refrigeration system, recover
HFC134a refrigerant for safe disposal.

Every time sealed HFC134a system is repaired, drier
filter must be replaced with, part # B2150504.

Cut drier out of system by completing the following
steps. Do not unbraze drier filter. Applying heat to
remove drier will allow moisture into system.
1. Score capillary tube close to drier and break.
2. Reform inlet tube to drier allowing enough space

for large tube cutter.

3. Cut circumference of drier at 1-1/4", below

condenser inlet tube joint to drier.

4. Remove drier.
5. Apply heat trap paste on post condenser tubes to

protect grommets from high heat.

6. Unbraze remaining part of drier. Remove drier

from system.

7. Discard drier in safe place. Do not leave drier with

customer. If refrigerator is under warranty, old
drier must accompany warranty claim.

HFC134a Service Information

DANGER

To avoid death or severe personal injury, cut
drier at correct location. Cutting drier at incorrect
location will allow desiccant beads to scatter.
Completely clean area of beads, if spilled.