Danger, Operating instructions – IPA Tools 9008-SE Super MUTT Standard Edition User Manual
Page 20

20
OPERATING INSTRUCTIONS
FOR AIR BRAKE CONTROLS
DANGER
WARNING!! BEFORE CONNECTING AIR TO TESTER PANEL,
BE SURE TO CHOCK ALL WHEELS ON TRAILER TO PREVENT
TRAILER FROM ROLLING. TRAILER CAN ROLL AND CAUSE
SERIOUS INJURY OR DEATH.
DO NOT CONNECT SHOP AIR UNTIL COMPLETING THE PRE-TEST PROCE-
DURES STEPS 1 THROUGH 7 (PAGE 21). FAILURE TO FULLY UNDERSTAND
THESE WARNINGS CAN RESULT IN MINOR TO SERIOUS INJURY AND
POSSIBLY DEATH.
AIR PANEL (Fig. 7)
A. Emergency Side – Air Out To Red Hose
B. Emergency Side – Gauge
C. Emergency Side – Ball Valve
D. Air Regulator – Knob
E. Service Side – Ball Valve
F. Service Side – Gauge
G. Service Side – Air Out To Blue Hose