Calibrate the screws with the torque wrench as indicated in paragraph 3. “SCREW CALIBRATION”

Insert the O-ring on the inspection covers (1, fig. 144) and mount the covers using 4 + 4 M6 x 14 screws

(1, fig. 145).

2.2.5 Manifold Refurbishment

Manifold cavitation damages around the three cylinder bores can be fixed by re-tooling the damaged bores

to a larger diameter (see fig. 146 for MK40A, 45A-50A and fig. 148 for MK55A-60A-65A).