beautypg.com

Mk series – General Pump MK Repair Manual User Manual

Page 39

background image

GENERAL PUMP

A member of the Interpump Group

MK SERIES

Page 39

Insert the 14 x 2 O-ring in its correct seat on the plunger bolt (1, fig. 136).

Assemble the plungers on their respective guides (1, fig. 137) and fasten them as in 1, fig. 138).

Calibrate the screws using the torque wrench as indicated in paragraph 3. “SCREW CALIBRATION”

Position the wiper complete with its O-rings in its seat on the plunger guide (1, fig. 134 and fig. 135).