beautypg.com

Mk series – General Pump MK Repair Manual User Manual

Page 16

background image

GENERAL PUMP

A member of the Interpump Group

MK SERIES

Page 16

Completely insert the pressure sleeve on the shaft from the opposite side of the PTO (1, fig. 49 and fig. 50).

Pressure sleeve insertion must be done without oil or lubricants.

Insert the sleeve until the external surface (tapered) couples perfectly with the inside of the

bearing. During insertion, be sure that the bearing remains in contact with the shaft shoulder.

Measure the dimension “X” indicated in fig. 51.