Calibrate micro module, Way toggle mode (latching switches only, default) – INSTEON Micro Open/Close - 2444-222 (US), 2444-422 (EU), 2444-522 (AUS/NZ) Manual User Manual
Page 8

Page 8 of 21
2444-222/2444-422/2444-522 - Rev: 2/24/2014 9:10 AM
Calibrate Micro Module
Once wired in, you need to calibrate Micro module for the time it takes for your application—shutters, blinds,
projector screens, etc.—to fully raise/lower or open/close. Do not walk away during the calibration process as your
Set button taps will determine the timing. These settings can also be configured remotely via software (sold
separately).
1) Press and hold Set button until it beeps
LED will start blinking green
2) Press and hold Set button until it beeps again
LED will start blinking red
3) Press and hold Set button until it beeps a third time
LED will start blinking green
4) Press and hold Set button until it beeps a fourth time
LED will start blinking red
5) Slowly tap Set button twice
LED will continue blinking red
6) Press and hold Set button until it beeps
Motor will begin travelling one direction
7) As soon as load is fully lowered (or raised), tap Set button
Motor will begin travelling the opposite direction
8) As soon as load is fully raised (or lowered), tap Set button
Micro module will double-beep
Micro module is now calibrated
3-Way Toggle Mode (Latching Switches Only, Default)
Because Micro module comes programmed for latching switches, 3-way toggle mode is enabled by default.
Normally, a latching switch reads the switch’s up position as on and down position as off. For example, if you turn
Micro module on from the latching switch and off from another controller, the switch is still in the up position; turning
Micro module back on from the switch would require you to tap the switch down, then up again.
The 3-way toggle mode overrides this sense feature, so in that same scenario—turning Micro module on at the
switch and off from another controller, so switch is in up position—you could then turn Micro module on at the switch
by tapping it down.
If you are installing Micro module behind a single or dual momentary switch, 3-way toggle mode is ignored. If
desired, you can disable (or re-enable) 3-way toggle mode by following these instructions:
1) Press and hold Set button until it beeps
LED will start blinking green
2) Press and hold Set button until it beeps again
LED will start blinking red
3) Press and hold Set button until it beeps a third time
LED will start blinking green
4) Press and hold Set button until it beeps a fourth time
LED will start blinking red
5) Tap Set button
Micro module will beep and LED will start double-blinking red
6) Press and hold Set button until it double-beeps
LED will stop blinking
3-way toggle mode is now disabled (or re-enabled)