Section 4 Maintenance

Installation and Operation Manual

X-TMF-5851E-MFC-eng

Part Number: 541B104AAG

November, 2008

Figure 4-3 Voltmeter Connections for Valve Adjustment

Section 4-4A. Note the number, locations and thickness of all
spacers (9 and 10).

d. Decrease the preload of the valve by 0.005 inches by either remov-

ing a 0.005 inches small preload spacer or by adding a 0.005 inches
large preload spacer. Refer to Figure 4-2.

e. Reassemble the valve following the assembly procedure in Section

4-4A.

f. Command 0% flow, apply normal operating gas pressure and check

for valve leak-thru by observing the output signal.

g. If the valve leaks-thru increase the preload by 0.005" and go to Step

h. If the valve does not leak-thru repeat Steps d, e, f and g.

h. Apply the normal operating gas pressure and command 100% flow

(5.000 Volts on Terminal A, Pin 2).

1.95 x TP3 + 33.4