Socket Base
Filename: GHI.mcd, Rev A, 1/18/00, IP
Target PCB with SMT pads
Socket
Top Assembly
Compression Screw
Compression plate
BGA Package
Z-Axis Elastomer
Machine Screw
Socket Lid
Machine Screw
Alignment plate
GH
Z
BGA Socket
(direct mount - hardware)
Assembly Instructions
© 2000 IRONWOOD ELECTRONICS, INC.
Tele: (800) 404-0204
www.ironwoodelectronics.com
1. Install the socket base on top of alignment plate on the target PCB with the hardware provided.
2. Place the square piece of elastomer provided into the socket base (rotation and 'side up' orientation are not critical).
3. Adjust the elastomer to sit into the alignment plate cavity.
4. Place BGA package (solder ball side down) into the socket. NOTE: BGA orientation on target PCB is critical.
5. Place the compession plate (if required*) on top of the BGA package.
6. Install the socket top assembly with the hardware provided (four 0-80 screws).
7. Turn the compression screw clockwise, until it makes contact with the compression plate or the BGA package.
8. Turn an additional quarter-turn.
*Ironwood Electronics technical staff will determine (from your package spec) if a compression plate is required