beautypg.com

Ironwood Electronics GHZ BGA Socket (Surface Mount) Assembly Instructions User Manual

Bga socket, Surface mount) assembly instructions

background image

Socket
Top Assembly

Compression Screw

Compression plate

BGA Package

Z-Axis Elastomer

Socket Base Assembly

Machine Screw

Target PCB with SMT pads

Socket Lid

Alignment plate

GH

Z

BGA Socket

(surface mount)

Assembly Instructions

© 2000 IRONWOOD ELECTRONICS, INC.

Tele: (800) 404-0204

www.ironwoodelectronics.com

1. Reflow Socket Base assembly to the target PCB (see page 2 for reflow profile).

2. Place the square piece of elastomer provided into the socket base (rotation and 'side up' orientation are not critical).

3.

Adjust the elastomer to sit into the alignment plate cavity.

4. Place BGA package (solder ball side down) into the socket. NOTE: BGA orientation on target PCB is critical.

5. Place the compession plate (if required*) on top of the BGA package.

6. Install the socket top assembly with the hardware provided (four 0-80 screws).

7. Turn the compression screw clockwise, until it makes contact with the compression plate or the BGA package.

8. Turn an additional quarter-turn.

*Ironwood Electronics technical staff will determine (from your package spec) if a compression or alignment plate is required

page 1 of 2

Filename: HSI.mcd, Rev A, 1/18/00, IP