AT Command Syntax

Description of Command

AT SWVER? or ATI1

Read the software code version
downloaded in the Modem from the
System Table.
Data encrypted version: U-D_1000
(Version #) (Date Time)
Non encrypted version: No Encrypt
Version #)(Date Time)
Response: U-D_1000 (Version #)
(Date Time)
No Encrypt (Version #) (Date Time)

AT VERBOSE?

Read 1 for verbose or 0 for terse modes
from the System Table.
Response: Verbose 0 or Verbose 1
Verbose 0 means terse mode is on,
Verbose 1 means verbose mode is on.

AT CLRAUTH NEI n

Clear Authentication parameters for NEI #n.
WARNING: Check with your service
provider before taking this step.
Response: OK

AT CMPR <1><0>

Set TCP/IP Header Compression Mode.
(On/Off)
Response: OK

AT FC <1><0>

Set flow control mode (On/Off).
(When hardware flow control is enabled,
the Modem generates CTS when it is able to
accept characters, otherwise it will de-assert
CTS. The Modem inhibits output to the
serial line when the host de-asserts RTS;
otherwise it will permit output.)
Response: OK