Appendix – NEC PlasmaSync 42PD3 User Manual
Page 62
62
Ⅵ
Ⅵ
Ⅵ
†
P
LASMA
M
ONITOR
Appendix
47. CONFIG MENU Select
Function
The master monitor selects the CONFIG set-
tings of the slave.
Transmission data
CFH UA1 UA2 06H 01H DATA00 CKS
DATA00
Bit0 Bit1 : OSD DISPLAY
0
0
: BASIC
1
0
KEY
0
1
OFF
0
0
disabled
Bit2
0 : OSD MODE BASIC
1 : OSD MODE PRO
Bit3 Bit4 : SYNC CONTROL
0
0
AUTO
1
0
GSYNC
0
1
CSYNC
Bit5
0 : PLE LINK OFF
1 : PLE LINK ON
Bit6,7
0 (fixed)
ACK
6FH UA1 UA2 06H 01H DATA00 CKS
48. TIMER PROGRAM Setting
Function
The master sets timer program of the slave.
Transmission data
CFH UA1 UA2 08H 0CH DATA00 – DATA11 CKS
DATA00 Program No.
01H – 07H: Nos. 1 – 7
DATA01 Date (Month) Setting
01H – 09H: 1 – 9
10H – 12H: 10 – 12
AAH: When the date (day) is set to “Every-
day” or “Every Sun. - every Sat.”.
FFH: - (No setting)
DATA02 Date (Day) Setting
00H: Everyday
01H – 09H: 1- 9
10H – 19H: 10 – 19
20H – 29H: 20 – 29
30H – 31H: 30 – 31
40H – 46H: Every Sun. – every Sat.
FFH: - (No setting)
DATA03 ON Time (HOUR)
00H: 00 - 09
10H – 19H: 10 – 19
20H – 23H: 20 – 23
FFH: - (No setting)
DATA04 ON Time (MIN)
00H – 09H: 00- 09
10H – 19H: 10 – 19
20H – 29H: 20 – 29
30H – 39H: 30 – 39
40H – 49H: 40 – 49
50H – 59H: 50 – 59
FFH: - (No setting)
DATA05 OFF Time (HOUR)
00H – 09H: 00 - 09
10H – 19H: 10 – 19
20H – 23H: 20 – 23
FFH: - (No setting)
DATA06 OFF Time (MIN)
00H – 09H: 00- 09
10H – 19H: 10 – 19
20H – 29H: 20 – 29
30H – 39H: 30 – 39
40H – 49H: 40 – 49
50H – 59H: 50 – 59
FFH: - (No setting)
DATA07 Mode
00H:VIDEO
01H:RGB1
02H:RGB2/HD/SCART
03H:RGB3
04H:INV
05H:WT
06H:RP
07H:RI
FFH: - (No setting)
DATA08 Repeat Program MODE1
00H:VIDEO
01H:RGB1
02H:RGB2/HD/SCART
03H:RGB3
04H:INV
05H:WT
FFH: - (No setting)
DATA09 Repeat Program TIME1
00H: 1 min
01H: 2 min
02H: 3 min
03H: 4 min
04H: 5 min
05H: 7 min
06H: 10 min
07H: 15 min
08H: 30 min
DATA10 Repeat Program MODE2
00H:VIDEO
01H:RGB1
02H:RGB2/HD/SCART
03H:RGB3
04H:INV
05H:WT
FFH: - (No setting)
DATA11 Repeat Program TIME2
00H: 1 min
01H: 2 min
02H: 3 min
03H: 4 min
04H: 5 min
05H: 7 min
06H: 10 min
07H: 15 min
08H: 30 min
ACK
6FH UA1 UA2 08H 00H CKS
49. MULTI DISP MODE Select
Function
The master switches DISP MODE of the slave.
Transmission data
CFH UA1 UA2 07H 02H DATA00 DATA01 CKS
DATA00 (DISP MODE)
BIT0 0: SPLIT
1: BLANKING
The other bits shall be fixed at 0.
DATA01 (Spare): DON’T CARE
ACK
6FH UA1 UA2 07H 02H DATA00 DATA01 CKS
DATA00 (DISP MODE)
BIT0 0: SPLIT
1: BLANKING
The other bits shall be fixed at 0.
DATA01 (Spare): DON’T CARE
50. MULTI DISP MODE Request
Function
The master requests the DISP MODE settings
of the slave.
Transmission data
CFH UA1 UA2 61H 02H DATA00 DATA01 CKS
DATA00 (DISP MODE)
BIT0 0: SPLIT
1: BLANKING
The other bits shall be fixed at 0.