RS-232C
$
Audio control commands
Sends data of computer
Return data from VTR
Description of command
[STX] AOC:m [ETX]
Parameters
m = 1: CH1
2: CH2
3: CH3
4: CH4
5: CH1 & CH2
6: CH3 & CH4
7: CH1+3 & CH2+4
[STX] AOC [ETX]
Sets the audio signal output channel/s. Playback output is
possible for CH3 and CH4 when audio signals for 4
channels have been recorded on a DV format tape.
is being processed.
$
Counter control commands
Sends data of computer
Return data from VTR
Description of command
[STX] CCP:data [ETX]
Parameters
data = ghmmssff
g = Blank: With a positive value
– sign: With a negative value
h =
0
9:
Hours
mm = 00
59: Minutes
ss =
00
59: Seconds
ff =
00
29: Frames
[STX] CCP [ETX]
Presets the designated counter value on the CTL counter.
The value will be corrected as follows if the non-drop frame
preset value has been set while the drop frame mode is
established.
00:01:00:00
00:00:59:28
00:01:00:01
00:00:59:29
is being processed or while the tape is being ejected.
[STX] CDF [ETX]
[STX] CDF [ETX]
Disables the drop frame mode setting.
CTL and the time code are set to the non-drop frame mode.
The non-drop frame is enabled for the time code when it is
being recorded.
is being processed, during recording and in the INSERT
mode.
[STX] CDN [ETX]
[STX] CDN [ETX]
Enables the drop frame mode setting.
CTL and the time code are set to the drop frame mode.
The drop frame is enabled for the time code when it is being
recorded.
is being processed, during recording and in the INSERT
mode.
[STX] CHM:m [ETX]
Parameters
m = 1: 12-hour mode
2: 24-hour mode
[STX] CHM [ETX]
Sets the CTL display to the 12-hour mode or 24-hour mode.
is being processed.