beautypg.com

Setup menus, Interface menu – Panasonic AJ-D250P User Manual

Page 30

background image

30

INTERFACE menu

The underlining denotes the factory mode setting.

Setup Menus

Item

Setting

No.

Superimposed

display

No.

Superimposed

display

Description of setting

200

BAUD RATE

0000
0001
0002
0003
0004

1200
2400
4800

9600

19200

For setting the RS-232C transmission speed (baud rate).

201

DATA LENGTH

0000
0001

8BIT

7BIT

For setting the RS-232C data length.

202

STOP BIT

0000
0001

1BIT

2BIT

For setting the RS-232C stop bit.

203

PARITY

0000
0001
0002

NONE

ODD

EVEN

For setting none, odd or even as the RS-232C parity bit.
0: The parity bit is not used.
1: Odd parity is used for the parity bit.
2: Even parity is used for the parity bit.

204

ACK RETURN

0000
0001

OFF

ON

For setting the RS-232C return data.
0: The ACK code is not returned.
1: The ACK code is returned.

205

232C ID SEL

0000

0001

D250

D230

For setting the RS-232C device ID.
0: The ID of the AJ-D250 is returned.

Use this setting when exercising control using the AJ-A250 or a
computer.

1: The ID of the AJ-D230 is returned.

Use this setting when exercising control using the AJ-A571.
When the AJ-A571 is used for control, the unit can be used as a player
VTR.