Installation, For qualified installers only), Installation example: class a chimney retrofit – Lopi Yankee PS User Manual
Page 16: Travis industries
![background image](/manuals/168429/16/background.png)
1 6
Installation
(For Qualified Installers Only)
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Installation Example: Class A Chimney Retrofit
Vent
Clearance*
Vent
Clearance*
Type "L" Vent
6” Minimum
Floor Protection
2”
Minimum
9” Minimum
“Tee”
Outside
Air
(optional)
Floor Protection
Outside air may be drawn from
a ventilated crawl space.
2” Min.
Class A Chimney Ceiling Support
Roof Flashing
“L” Vent to Class A Chimney Adapter
Class A Chimney
“L” Vent
Storm Collar
Class A Chimney must
maintain clearances outlined
in the chimney’s installation
instructions (usually 2”).
Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
between sections.
500
° F. RTV
Silicone
*
Install vent at clearance specified by the vent manufacturer.