Installation, For qualified installers only), Mobile home requirements – Lopi Yankee PS User Manual
Page 11: Outside air (used for combustion), Travis industries
![background image](/manuals/168429/11/background.png)
Installation
(For Qualified Installers Only)
1 1
© Travis Industries
4080728
1 0 0 - 0 1 1 5 6
Mobile Home Requirements
•
Outside air is required (used for
combustion) - see the directions
below.
•
The heater must be bolted to the
floor (Some states do not require
this; check with your local building
department). See the illustration
to the right.
•
The heater must be grounded to
the steel chassis of the mobile
home (Some states do not require
this; check with your local building
department).
WARNING:
DO NOT INSTALL IN
SLEEPING ROOM.
CAUTION:
THE STRUCTURAL
INTEGRITY OF THE
MANUFACTURED HOME
FLOOR, WALL, AND
CEILING/ROOF MUST BE
MAINTAINED.
7/16”
Socket
Remove the ash pan
(see page 29).
Use the lag bolts (used
to secure the stove to
the pallet) to screw the
pedestal to the floor.
a
b
Outside Air (used for combustion)
•
Must not be drawn from an enclosed space (garage, unventilated crawl space).
HINT:
Travis Industries strongly suggests outside air for all residential installations, especially for
those that are energy efficient, air-tight homes.
•
Must not be over 15' long.
•
Must be made with 1 3/4"
diameter or larger metal or
aluminum duct with a metal
screen attached to the end
to keep out rodents
(P.V.C. or other
combustible materials may
not be used). We
recommend the Travis
Industries Outside Air Kit
(part # 99200136).
•
Must not terminate above
or within 1' of the chimney
termination.
•
Must have a rain cap or
down-turned elbow to
prevent water from
entering.
•
Must be located so that it
will not become plugged by
snow or other material.
13"
9-1/4"
1-3/4" Diameter Flex Duct
Select a location
between framing
members for the
outside air hole.
Rain Hood with Rodent Screen
Silicone
Cut a minimum 2" diameter
hole in the wall.
Silicone
Seal the area around
the tube to prevent
air from entering
through the wall.
Silicone
NOTE:
This valve must be open (the rod
parallel with the tube) when the
stove is in operation.