beautypg.com

Chapter 4 troubleshooting, Introduction, License reject – StorageTek StorageNet SCSI-3 User Manual

Page 37: Check condition, Invalid field errors, Chapter 4 “troubleshooting, Describes command error messages, Introduction -1, License reject -1, Check condition -1

background image

8946121402

4-1

Chapter 4 Troubleshooting

Introduction

This chapter discusses the

SEND DIAGNOSTIC

command error messages.

License Reject

A license reject is generated when the SES license key is improperly entered or is not
installed.

The following message is generated:

Probable cause:

Invalid Field

Action:

See the

“Reject”

section in

Chapter 3

for more information.

CHECK CONDITION

CHECK CONIDITION

is generated when the SES Device (SESD) terminates an operation

because an error was encountered. These error conditions can be from invalid operations,
warning indications and failure conditions. The sense key and sense code describe the error.

Invalid Field Errors

ILLEGAL REQUEST

is generated from any invalid fields in the CDB, from parameters of a

SEND DIAGNOSTIC

command and from the CDB of a

RECEIVE DIAGNOSTIC RESULTS

command. The sense code identifies the location of the invalid fields, parameter or CDB.

The following message is generated:

Probable cause:

Invalid Field

Action:

See the

“Reject”

section in

Chapter 3

for more information.