Table 3-14 – StorageTek StorageNet SCSI-3 User Manual
Page 29
FCP and SES Commands
8946121402
3-9
Table 3-14 Fibre Channel Port Table Page Format
Byte/Bit
Field #
Access
7
6
5
4
3
2
1
0
0
na
na
Page Code = 84h
1
na
na
Reserved
2 .. 3
na
na
Page Length =
n - 3
4 .. 7
na
na
swNumEntries =
i – specifies the number of entries received.
Note: Each entry consists of swValidity[0] field through field 27.
8 .. 11
na
rw
swValidity[0]
12 .. 15
0
ro
swFCPortIndex[0]
16 .. 19
1
ro
swFCPortType[0]
20 .. 23
2
ro
swFCPortPhyStatus[0]
24 .. 27
3
ro
swFCPortOpStatus[0]
28 .. 31
4
rw
swFCPortAdmStatus[0]
32 .. 35
5
ro
swFCPortTxWords[0]
36 .. 39
6
ro
swFCPortRxWords[0]
40 .. 43
7
ro
swFCPortTxFrames[0]
44 .. 47
8
ro
swFCPortRxFrames[0]
48 .. 51
9
ro
swFCPortTxC2Frames[0]
52 .. 55
10
ro
swFCPortTxC3Frames[0]
56 .. 59
11
ro
swFCPortRxLCs[0]
60 .. 63
12
ro
swFCPortRxMcasts[0]
64 .. 67
13
ro
swFCPortTooManyRdys[0]
68 .. 71
14
ro
swFCPortNoTxCredits[0]
72 .. 75
15
ro
swFCPortRxEncInFrs[0]
76 .. 79
16
ro
swFCPortRxCrcs[0]
80 .. 83
17
ro
swFCPortRxTruncs[0]
84 .. 87
18
ro
swFCPortRxTooLongs[0]
88 .. 91
19
ro
swFCPortRxBadEofs[0]
92 .. 95
20
ro
swFCPortRxEncOutFrs[0]
96 .. 99
21
ro
swFCPortRxBadOs[0]
100 .. 103
22
ro
swFCPortRxC3Discards[0]
104 .. 107
23
ro
swFCPortMcastTimedouts[0]