Controller leds, Battery unit leds – IBM System Storage Subsystem DS5020 User Manual
Page 134

Table 14. Battery unit LEDs
LED
Normal Status
Problem Status
Service Action
Allowed (OK to
Remove)
Off
On
Service Action
Required (Fault)
Off
On
Battery Charging
Green means on,
ready
Blinking green means
charging
Off
The Global Power, Global Summary Fault, and Global Locate LEDs are general
indicators for the entire DS5020 storage subsystem (or configuration, in the case of
the Global Summary Fault). The Global Summary Fault LED turns on if a fault
condition is detected in any component in the storage subsystem configuration,
including all attached storage expansion enclosures. The Global Power, Global
Summary Fault, and Global Locate LEDs shine through the front bezel.
Attention:
If the Global Summary Fault LED lights, refer to the DS Storage
Manager client software to determine the problem with the storage subsystem. Also,
inspect the Needs Attention LEDs on the other components in the storage
subsystem to help isolate the fault to a specific component.
Controller LEDs
This section describes the primary LEDs, controls, and connectors on the rear of
the storage subsystem controller.
Figure 69 on page 105, Figure 70 on page 105, and Figure 71 on page 106 show
the three different DS5020 controller configurations that are available. Figure 69 on
page 105 shows the base DS5020 storage subsystem, with two Fibre Channel host
ports. For more information about DS5020 controller options and other components,
see the “Parts listing” on page 160.
Service action
allowed (ok to
remove) LED
Service action
required
(fault) LED
Battery
charging
LED
Service action
allowed (ok to
remove) LED
Service action
required
(fault) LED
Battery
charging
LED
Figure 68. Battery unit LEDs
104
IBM System Storage DS5020 Storage Subsystem: Installation, User’s, and Maintenance Guide