InFocus MaxFlight MT3000(B) User Manual
Page 44

Parameter Description
Pitch Roll Lift Weight
7 Acceleration
time
1.0 0.1 0.1
1.0
8 Deceleration
time
1.0 0.1 0.1
1.0
9 Electric thermal O?L relay
13.1/6.5 8.5/4.2 8.5/4.3 0.7
10 DC injection brake operation
4
1
1
3
12 DC injection brake voltage
4.0 3.0 3.0
3.0
15 Jog
frequency
10.00 10.00 10.00
60.00
16 Jog
acceleration/deceleration
time .5 .5 5 0.1
22 Stall prevention level
175 175 175
0
29 Acceleration/deceleration
pattern 1
0
0
0
30 Regenerative function selection
1 1 1
0
60 Intelligent
mode
selection
0
0
0
0
70 Special regenerative brake duty
30.00 30.00 30.00
71 Applied
motor
13 13 13
3
72 PWM frequency selection
11 11 11
15
73 0-5V/0-10V
selection
14 14 14
77 Parameter write disable selection
2 2 2
2
79 Operation mode selection
1* 1* 1*
1*
80 Motor
capacity
3.7 3.7 2.2
0.1
81 Number of motor poles
4 4 2
82 Motor exciting current***
83 Rated motor voltage
230.0 230.0 208.0
208.0
84 Rated motor frequency
60 60 60
60
90 Motor constant (R1)***
91 Motor constant (R2)***
92 Motor constant (l1)***
93 Motor constant (L2***
96 Auto
tuning
setting
3 3 3
1
117 Station
number
0
1 2 3
121 Number of communication retries
9999 9999 9999
9999
122 Communication check time
interval
9999 9999 9999
9999
145 PU language select
1 1 1
1
190 RUN terminal function selection
0*
0*
0*
0*
192 ABC terminal function selection
195 ABC terminal function selection
99
99
99
244 Cooling fan operation selection
1 1 1
1
903 Frequency setting voltage gain
120.0 120.0 120.0
60.0
Changed 4 Oct. 00
* Parameters 79 and 190 are adjusted during operation by the MFMotion software and may vary
after the unit has been operated once after initial configuration. It is usually not necessary to reset
these values again.
*** Parameters 82, 90, 91, 92, and 93 are configured during auto-tuning and are only visible and
updatable while parameter 77 is set to 801. They can be configured directly instead of auto-
tuning the inverter. If an inverter was auto-tuned, the values may vary from those shown.