ICP DAS USA IM-100 User Manual
Page 84

IMC_Trigger_Disable
Syntax:
Visual C++ 6.0 / Boland C++ Builder 6.0:
short IMC_Trigger_Disable ( HANDLE Camera_Handle);
Visual Basic 6.0
IMC_Trigger_Disable (ByVal Camera_Handle As Long) As Integer
C#.NET 2003
Mavis.IMC_Trigger_Disable( IntPtr Camera_Handle);
Description:
This function disables the External Trigger. The camera needs be initialized with
IMC_Camera_Init().
Parameters:
Camera_Handle
The handle for MAVIS camera. Use the handle gotten from the
‘pHandle’ parameter of IMC_Camera_Init().
Return:
ERROR_SUCCESSFUL Successfully
ERROR_CAMERA_CREATE
The Camera_Handle is NULL.
ERROR_DEVICE_UNINIT
The specific camera has not been initialized.
ERROR_INVALID_CAMERA
The handle is invalid.
-
84
-
This manual is related to the following products: