beautypg.com

2 test pattern – ICP DAS USA IM-100 User Manual

Page 6

background image

current settings is 5.

Formula 1:

Max. Frames/s = 1 / (((240 + 2) x 15.28us) + 15.28us)

Max. Frames/s = 269.2

Formula 2:

Max. Frames/s = 1 / (5 x 125us)

Max. Frames/s = 1600

Formula 3:

Max. Frames/s = 1 / (1000 us + 28us)

Max. Frames/s = 972.76

By using the calculations above, the AOI for this particular scenario can be

calculated at 269 frames per second.

1.4.2 Test Pattern

The MAVIS IM-30/IM-100 series cameras offer an internal generated test

pattern for testing camera transmission. The test pattern will show a gray

bar running diagonally, moving upwards at 1pixel/frame.

Figure 1-2: MAVIS IM-30/IM-100 gray bar test pattern

When setting camera to test pattern mode, then camera will

keep this configuration even after rebooting the camera. Please

be sure to disable test pattern mode after your test completed

testing.

-

6

-

This manual is related to the following products: