beautypg.com

Pinout assignments – IBM AT-FS202SC/FS3 User Manual

Page 32

background image

Technical Specifications

24

Table 11 Fiber Optic Loss Specification (Benchmark)

Pinout Assignments

Figure 5 shows the pin assignments of the RJ-45 connector.

Figure 5 RJ-45 Pin Assignments

AT-FS202SC/
FS3

9/125
SMF

33.00 dB

35.00 dB

15 km (9.4
mi)

75 km (46 mi)

AT-FS202SC/
FS4

9/125
SMF

34.0

35.5 dB

40 km
(24.8 mi)

100 km (62
mi)

1. MMF = Multimode Fiber / SMF = Single-mode Fiber.
2. The recommended minimum range is stated in all cases where the maximum transmitter output power

exceeds the receivers saturation level. This is to prevent blinding or burning out of the optical receiver
on the far-end node.

Fiber
Type

1

1. MMF = Multimode Fiber / SMF = Single-mode Fiber.

Fiber
Optic
Diameter

Optical
Wavelen
gth

Typical
Loss
Factor

Worst
Case Loss
Factor

Bandwidth

MMF

50/125
microns

1310 nm

1.00 dB/
km

1.50 dB/
km

400 Mhz-
km

62.5/125
microns

1310 nm

1.00 dB/
km

1.50 dB/
km

500 Mhz-
km

SMF

9/125
microns

1310 nm

0.40 dB/
km

1.00 dB/
km

Not
applicable

SMF

9/125

1550 nm

0.30 dB/
km

0.75 dB/
km

Not
applicable

Model

Fiber

Type

1

Minimum
Power/
Link
Budget

Average
Signal
Loss (dB)

Minimum
Distance
Specs.

2

Maximum
Distance
Specs.

8

8

1

1

This manual is related to the following products: