beautypg.com

IBM AT-FS202SC/FS3 User Manual

Page 11

background image

AT-FS20x Series Installation Guide

3

Table 1 lists the maximum operating distances for the switches.

Table 1 Maximum Operating Distances

Model

100Base-FX

10/100Base-TX

Connector

Maximum
Operating
Distance

1

1. Maximum distance for 100 Mbps optical datalinks is dependent on the following factors: type of optical

fiber, duplex mode of both end-nodes, and maximum optical loss budget for each of the optical fiber at
the operating optical wavelength.

Connector

Maximum
Operating
Distance

2

2. Maximum distance can only be obtained when the UTP/STP cabling is installed and verified to TIA/EIA

568A Commercial Building Telecommunications Cabling Standard.

AT-FS201

ST

2 km (1.2 mi)

RJ-45

100 m (328 ft)

AT-FS202

SC

2 km (1.2 mi)

RJ-45

100 m (328 ft)

AT-
FS202SC/
FS1

SC

15 km (9.3 mi)

RJ-45

100 m (328 ft)

AT-
FS202SC/
FS2

SC

40 km (24.8
mi)

RJ-45

100 m (328 ft)

AT-
FS202SC/
FS3

SC

75 km (46.5
mi)

RJ-45

100 m (328 ft)

AT-
FS202SC/
FS4

SC

100 km (62 mi)

RJ-45

100 m (328 ft)

This manual is related to the following products: