Mitsubishi Motors DS5000TK User Manual
Page 88
![background image](/manuals/123320/88/background.png)
USER’S GUIDE
050396 87/173
88
Timers
The microprocessor disables timer activity (excluding
the Watchdog) and serial port communication on a re-
set. Therefore, each timer must be setup and enabled
as part of the reset routine. The serial port mode must
also be initialized if used. This is covered in detail in the
User’s Guide section on Timers and Serial I/O respec-
tively. Shown here is an example of Timer and Serial
Port setup. In this example, Timer 0 is set up to generate
a 10 ms interrupt. Timer 1 is setup to generate 9600
baud for the serial port. The serial port is set up for
asynchronous communication with a PC (mode 1). A
crystal frequency of 11.0592 MHz is assumed.
ORG 00h
SJMP
Start
Org
30h
Start :
SETB
PS
;Set Serial Port Interrupt to High Priority
SETB
ES
;Enable Serial Port Interrupt
SETB
ET0
;Enable Timer 0 Interrupt
MOV
TMOD,
#00100001b
;Select Timer 1 mode 2 – 8 bit auto–reload,
; Timer 0 mode 1 – 16 bit manual reload
MOV
TH1,
#0FDh
;Setup 9600 baud
MOV
TL1,
#00h
; ” ”
MOV
TH0,
#0DBh
;Select a 10 ms count. 9216 counts = 10 ms
MOV
TL0,
#0FFh
; 9216d counts = 2400h counts (FFFFh–2400h =
; DBFFh)
; Timer 0 ISR must reload DBFFh manually
MOV
SCON,
#01010011b
;Select Serial Port mode 1,
; TXD and RXD interrupts active
MOV
TCON,
#01010000b
;Enable the operation of both Timers
SETB
EA
;Globally enable interrupts
Protection
The microprocessor provides protection from transients
through a built in power–fail/power–on reset and Watch-
dog Timer. Each of these functions should be initialized
by the user as part of the reset routine. The following
code demonstrates the set up for a user that will support
the Watchdog function.
TA
EQU
0C7h
ORG 00h
SJMP
Start
Org
30h
Start :
MOV
TA,
#0AAh
;Timed
MOV
TA,
#55h
; Access
ORL
IP,
#80h
;Set RWT to restart the Watchdog Timer
MOV
TA,
#0AAh
;Timed
MOV
TA,
#55h
; Access
ORL
PCON,
#44h
;Set POR (PCON.6) bit for power on reset detect