;This code example shows how to initialize the serial port and transmit /
; receive code as described above.
TA
Equ
0C7h
MCON
Equ
0C6h
Org
00h
Reset :
SJMP
Start
Org
23h
Serial_ISR :
CLR
RI
;Clear receive flag
CLR
TI
;Clear transmit flag
RETI
;No special processing, return to application
Org
30h
Start :
MOV
TA, #0AAh
;Start Timed Access
MOV
TA, #55h
; finish Timed Access
MOV
MCON, #88h
;Select Partition at 4000h (DS5000)
CLR
RI
;Initialize receive flag
CLR
TI
:Initialize transmit flag
MOV
SCON, #50h
;Configure Serial Port for Mode 1 and enable receiver
MOV
TMOD, #20h
;Configure the Timer 1 for 8–bit auto–reload
MOV
TCON, #40h
;Enable the Timer 1
MOV
TH1, #0FDh
;Set Baud Rate
ANL
PCON, #7Fh
;Set SMOD=0
MOV
IP, #10h
;Set Serial Interrupt to high priority
MOV
IE, #90h
;Globally enable interrupts and Serial Interrupt
Send :
MOV
R0, #0FFh
;Set loop counter to 255
MOV
DPTR, #4000h
;Put the data pointer at the beginning of data memory
Send_Loop :
MOVX
A, @DPTR
;Get data byte
MOV
SBUF, A
;Transmit data byte
JNB
TI, $
;Wait for serial word to be sent (interrupt)
INC
DPTR
;Next byte to be sent
DJNZ
R0, Send_Loop
;Decrement loop counter
Receive :
JNB
RI, $
;Wait for incoming word (interrupt)
MOV
R1, SBUF
;Get received byte
CJNE
R1, #0A5h, Send ;Check for confirmation code
; and resend all data if wrong
End