Mvc8_ab, *dvc8_aa w, Iring, Iagram – Goodman Mfg VC8 User Manual

Page 47

background image

47

*MVC8_AB, *DVC8_AA W

IRING

D

IAGRAM

TO +VDC

TO

MICRO

TO

R

GND (4)

+ VDC (1)

RX (2)

TX (3)

CIRCULATOR

INDOOR

AIR

BLWR

RD

GY

BL

BK

PROPERLY POLARIZED

HUMIDIFIER

GND

PROTECTION DEVICE

HEAT OFF

DELAY

BURNER COMPARTMENT

24 V
3 A

BL

POWER SUPPLY WITH

LINE

12

TO

C

2

BK

RD

UNUSED

DISCONNECT POWER

4

IGNITER

FLAME SENSOR

INTEGRATED CONTROL MODULE

POWER BEFORE

YL

TERMINAL

HI

OR ORANGE

MVH (14)

CO
NN
E

C

T

O

R

PM

ECM MTR

HARNESS

NO

24 VAC

HI VOLTAGE FIELD

115kBTU MODELS

AUTO RESET PRIMARY

LIMIT CONTROL

BEFORE SERVICING.

RD

PS1 (2)

3

YL YELLOW

CIRCULATOR

BK

BR BROWN

4

BK

OVERCURRENT

24V HUM.

0140F00660 REV. A

IGNITER

115 VAC/ 1

BLOWER COMPARTMENT

24

BK

PM

1

WH WHITE

FUSE

15

INDUCED

DRAFT

BLOWER

EAC

C

3

BL BLUE

6

115 VAC

INDUCTOR COIL

WH

GND

5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST
RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE
IN STANDBY (NO THERMOSTAT INPUTS)

Ø /60 HZ POWER SUPPLY WITH

ADJUST

TO 115VAC/ 1

BK BLACK

DEHUM

5

HEAT

LINE

GND

24V HUM.

2

BK

HOT

SURFACE

IGNITER

MVC (8)

2

NEUTRAL

RD

WH

DOOR

LOW FIRE PRESS.
SWITCH

4

3

2

WH

VAC

GND

LOW VOLTAGE (24V)

2 CIRCUIT
CONNECTOR

HUM

DEHUM

2

HI VOLTAGE (115V)

OVERCURRENT

PSO (7)

WH

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE
USED WHEN SERVICING.

ONLY

C

AIR CLEANER

TWO STAGE

GAS VALVE

(HONEY WELL)

DISCONNECT

HIGH FIRE
PRESS. SWTICH

INDOOR

HUMIDIFIER

Ø /60 HZ

PK PINK

N

9

MANUAL RESET ROLLOUT
LIMIT CONTROLS

IND LO

14

40 VA

AUTO RESET AUXILIARY LIMIT

CONTROLS

HU
M

YL

JUNCTION

BLWR

PU PURPLE

1

CIRCULATOR
BLOWER

R

1

GND

JUNCTION BOX

SWITCH (TEMP.)

NEUTRAL

115kBTU MODELS

BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)

C

LINE

BK

YL

NEUTRAL

4

NEUTRAL

POLARIZED AND

11

C

FS

2

PLUG CONNECTION

DISCONNECT

PU

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH
WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT
LEAST 105 C. USE COPPER CONDUCTORS ONLY.

IN

T

E

G

R

A

T

E

D

CO
N

T

RO
L

MO
DU
LE

RD

INTEGRATED CONTROL

PROT. DEVICE

8

HIGH FIRE

PRESSURE

SWITCH

WH

ONLY

24 V THERMOSTAT CONNECTIONS

W1

INTERNAL TO

70kBTU,90kBTU,

NO

EQUIPMENT GND

MVL (13)

O

SERVICING. WIRING

2ND STG DLY

WH

RD

YL

ID BLOWER TWO-STAGE PRESSURE

SWITCH ASSEMBLY

BL

5

GND (5)

BK

IND HI

IGN

PK

HLO (10)

70kBTU,90kBTU,

NOTES:

PU

L

AIR

WH

MANUAL RESET ROLLOUT LIMIT

CONTROLS

Y1

GY GRAY

ELECTRONIC

RD RED

Y2

RD

NEUTRAL

1

HLI (1)

WH

SWITCH

AUTO RESET PRIMARY

LIMIT CONTROL

NO

TRANSFORMER

MUST BE PROPERLY

13

BL

3

OVERCURRENT PROTECTION DEVICE

T-STAT

5

BR

BK

2

GROUNDED.

LOW VOLTAGE FIELD

W2

DELAY

WARNING:

7

FIELD GND

FIELD SPLICE

SWITCH (PRESS.)

W2

WH

115

NEUTRAL

BLWR

3

GND

FS

1

AND GROUNDED.

4

GAS
VALVE

PU

INDUCTOR COIL

TH (4)

C

HI

24

V

H

U

M

.

TO UNIT MUST BE

VAC

G

YL

C

TR (11)

YL

GR

GN GREEN

HOT SURFACE

FLAME
SENSOR

PS2 (12)

LOW FIRE

PRESSURE

SWITCH

1

COLOR CODES:

L

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO
N.E.C. AND LOCAL CODES.

DIAGNOSTIC

LED'S

RD

3

10

WIRING TO UNIT

OR

NO

NEUTRAL

N

SEE
NOTE 5

BR

COOL

40 VA
TRANSFORMER

ID

TO
MICRO

WARNING:DISCONNECT

PU

AUTO RESET
AUXILIARY
LIMIT CONTROL

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

FUSE 3 A

2

24

V

T

H

E

R

M

O

S

TA

T

C

O

N

N

E

C

T

IO

N

S

5 C

IRC
UI

T

CO

NN
E

C

T

O

R

E

A

C

BK

4 C

IR

C

UI

T

M

O

T

O

R

3

T

W

O

-S

TA

G

E

1

DE
H

U

M

YL

YL

WH

R

IN

T

E

G

R

A

T

E

D

C

O

N

T

R

O

L M

O

D

U

LE

GN

W1

JU

NCTI

O

N B
O

X

WH

OR

BL

C

H

A

S

S

IS

GR

OU
N

D

BK

IN

T

E

G

R

A

T

E

D

C

O

N

T

R

O

L M

O

D

U

LE

G

Y2

O

2

1

YL

BR

WH

DI

P

S

W

IT

CH
E

S

Y1

WH

RD

1

C

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

H

IG

H

V

O

LTA

G

E

!

D

IS

CO

NNE

CT

AL

L

PO

WER

BE

F

O

RE

SE

R

V

IC

IN

G

OR

IN

S

T

A

LLI

N

G

TH

IS

UNI

T

.

M

U

LTI

P

L

E

PO

WER

S

O

U

RCE

S

MA

Y

BE

PR

E

S

EN

T

. F

AIL

U

RE

TO

DO

SO

MA

Y

CAU

S

E

PR

O

P

E

R

T

Y

DAM

AG

E

,

P

E

RS

O

NAL

INJ

URY

OR

DE

AT

H

.