Goodman Mfg VC8 User Manual

Page 34

background image

34

O

PERATIONAL

C

HECKS

& S

AFETY

C

IRCUIT

D

ESCRIPTION

H

EATING

M

ODE

The normal operational sequence in heating mode is as fol-
lows:

R and W1 (or R and W1/W2) thermostat contacts close,
initiating a call for heat.

Integrated control module performs safety circuit checks.

Induced draft blower is energized on high speed for a 15-
second prepurge. Humidifier terminal is energized with
induced draft blower.

Induced draft blower steps to low speed following
prepurge. Low stage pressure switch contacts are
closed.

Igniter warm up begins upon step to low speed and
presence of closed low stage pressure switch contacts.

LED LED

Status

Indication

Possible Causes

Corrective Action(s)

Notes & Cautions

Off

x Normal condition

x None

x None

x None

1 Flash

x Communications

Failure

x Communications

Failure

x Depress Learn Button
x Verify that bus BIAS

and TERM
dipswitches are in the
ON position.

x Depress once

quickly for a power-
up reset

x Depress and hold

for 2 seconds for
an out-of-box reset

Red

Communications

LED

2 Flashes

x Out-of-box reset

x Control power up
x Learn button

depressed

x None

x None

Off

x No power
x Communications

error

x No power to furnace
x Open fuse
x Communications error

x Check fuses and

circuit breakers;
replace/reset

x Replace blown fuse
x Check for shorts in

low voltage wiring in
furnace/system

x Reset network by

depressing learn
button

x Check data 1/ data 2

voltages

x Turn power OFF

prior to repair

1 Steady

Flash

x No network found

x Broken/ disconnected

data wire(s)

x Furnace is installed as

a legacy/ traditional
system

x Check

communications
wiring (data 1/ data 2
wires)

x Check wire

connections at
terminal block

x Verify furnace

installation type
(legacy/ traditional or
communicating)

x Check data 1/ data 2

voltages

x Turn power OFF

prior to repair

x Verify wires at

terminal blocks are
securely twisted
together prior to
inserting into
terminal block

x Verify data1 and

data voltages as
described above

Rapid

Flashing

x Normal network

traffic

x Control is “talking” on

network as expected

x None

x None

Green Receive

LED

On Solid

x Data 1/ Data 2

miss-wire

x Data 1 and data 2

wires reversed at
furnace, thermostat,
or CT™ compatible
outdoor AC/HP

x Short between data 1

and data 2 wires

x Short between data 1

or data 2 wires and R
(24VAC) or C (24VAC
common)

x Check

communications
wiring (data 1/ data 2
wires)

x Check wire

connections at
terminal block

x Check data 1/ data 2

voltages

x Turn power OFF

prior to repair

x Verify wires at

terminal blocks are
securely twisted
together prior to
inserting into
terminal block

x Verify data1 and

data voltages as
described above

N

ORMAL

S

EQUENCE

OF

O

PERATION

P

OWER

U

P

The normal power up sequence is as follows:

115 VAC power applied to furnace.

Integrated control module performs internal checks.

Integrated control module displays

88888 88888 on dual 7-segment

display LED’s.

Integrated control module monitors safety circuits
continuously.

Furnace awaits call from thermostat. Dual 7-segment
LED’s display

00000 PPPPP while awaiting call from thermostat.