DEFINE_EVENT 100065 CRITICAL DEFAULT # msg num 104
# [ 09 01 06 -- ] ----WR-O-- Tracking servo failure.
#---------------------------------------------------------
DEFINE_EVENT 100166 CRITICAL DEFAULT # msg num 105
# [ 09 02 06 -- ] ----WR-O-- Focus servo failure.
DEFINE_EVENT 100266 CRITICAL DEFAULT # msg num 106
# [ 09 03 04 -- ] ----WR-O-- Spindle servo failure.
#---------------------------------------------------------
DEFINE_EVENT 100067 CRITICAL DEFAULT # msg num 107
# [ 42 00 06 -- ] D--------- Power-on or self-test failure.
#---------------------------------------------------------
DEFINE_EVENT 100068 CRITICAL DEFAULT # msg num 108
# [ 40 00 06 -- ] D--------- Ram failure -- should use 40 nn.
#---------------------------------------------------------
DEFINE_EVENT 100069 CRITICAL DEFAULT # msg num 109
# [ 40 00 06 -- ] D--------- Ram failure -- should use 40 nn.
#---------------------------------------------------------
DEFINE_EVENT 100170 CRITICAL DEFAULT # msg num 110
# [ 47 00 06 -- ] DTLPWRSOMC Scsi parity error.
DEFINE_EVENT 100270 CRITICAL DEFAULT # msg num 110
# [ 47 00 0b -- ]
#---------------------------------------------------------
DEFINE_EVENT 100171 CRITICAL DEFAULT # msg num 111
# [ 46 00 0b -- ] DTLPWRSOMC Unsuccessful soft reset.
DEFINE_EVENT 100271 CRITICAL DEFAULT # msg num 111
# [ -- -- 0b -- ]
#---------------------------------------------------------
DEFINE_EVENT 100172 CRITICAL DEFAULT # msg num 112
# [ 04 00 02 -- ] DTLPWRSOMC Logical unit not ready, cause not reportable.
DEFINE_EVENT 100272 CRITICAL DEFAULT # msg num 113
# [ 04 01 02 -- ] DTLPWRSOMC Logical unit is in process of becoming ready.
DEFINE_EVENT 100372 CRITICAL DEFAULT # msg num 115
# [ 04 02 02 -- ] DTLPWRSOMC Logical unit not ready, init command required.
DEFINE_EVENT 100472 CRITICAL DEFAULT # msg num 116
# [ 04 03 02 -- ] DTLPWRSOMC Logical unit not ready, manual fix required.
DEFINE_EVENT 100572 CRITICAL DEFAULT # msg num 120
# [ 08 01 04 -- ] DTL-WRSOMC Logical unit communication time-out.
DEFINE_EVENT 100672 CRITICAL DEFAULT # msg num 183
# [ 25 01 05 -- ]
DEFINE_EVENT 100772 CRITICAL DEFAULT # msg num 117
# [ 29 00 06 -- ] DTLPWRSOMC Power on, reset, or bus device reset occurred.
DEFINE_EVENT 100872 CRITICAL DEFAULT # msg num 112
# [ 48 00 0b -- ]
DEFINE_EVENT 100972 CRITICAL DEFAULT # msg num 182
# [ 5d 00 01 -- ]
DEFINE_EVENT 101072 CRITICAL DEFAULT # msg num 165
# [ -- -- 02 -- ]
#---------------------------------------------------------
DEFINE_EVENT 100173 CRITICAL DEFAULT # msg num 118