beautypg.com

T8611m installation – Honeywell CHRONOTHERM III T8611M User Manual

Page 15

background image

15

68-0076—1

Fig. 7—Restrict wiring to recessed area surrounding terminals.

T8611M

INSTALLATION

DENOTES THERMOSTAT TO SUBBASE INTERCONNECT.

APPLICABLE ONLY ON MODEL WITH REMOTE SENSOR.

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

POSSIBLE CHECK LED CIRCUITS:

SOME OLDER HEAT PUMP THERMOSTATS USE X FOR COMMON TERMINAL.

NOMINAL 24 Vac POWER MUST BE PRESENT BETWEEN R AND C TERMINALS FOR THERMOSTAT OPERATION.

RECOMMENDED INTERCONNECT CABLE: 18-GAUGE THERMOSTAT CABLE, 200 ft. [61 m] MAXIMUM LENGTH. ROUTE
INTERCONNECT CABLE AWAY FROM SOURCES OF ELECTRICAL NOISE.

1

2

3

4

5

X2

X1

CHECK
LED
(YELLOW)

FAULT DETECTION
SWITCH

SWITCH TO R (POWER) SIDE OF
SYSTEM TRANSFORMER

TO R

TO C

X2

X1

CHECK
LED
(YELLOW)

FAULT DETECTION
SWITCH

SWITCH TO C (COMMON) SIDE
OF SYSTEM TRANSFORMER

TO R

TO C

X2

X1

CHECK
LED
(YELLOW)

SWITCHING
DEVICE

SWITCH IN SECONDARY OF
SEPARATE TRANSFORMER

L1
(HOT)

L2

24 Vac

1

M1018D

HEAT 2

L1
(HOT)

L2

HEAT

OFF

AUTO

SYSTEM
SWITCH

COOL 1

COOL 2

AUTO

ON

FAN
SWITCH

4

1

R

C

L

W3

W2

E

G

O

B

Y

Y2

X2

MONITOR

STAGE 2
HEAT RELAY

EMERGENCY
HEAT RELAY

FAN RELAY

CHANGEOVER
RELAY (HEAT)

STAGE 1 COMPRESSOR
CONTACTOR

STAGE 2 COMPRESSOR
CONTACTOR

3

C.O.

EM. HT.

COOL

X1

CHANGEOVER
RELAY (COOL)

EM. HEAT
LED (RED)

HIGH
LIMIT

C.O.

HEAT 1

HIGH
LIMIT

CHECK LED
(YELLOW)

2

S1

S2

S3

S1

S2

S3

202905 REMOTE
SENSOR

5

SUBBASE
LOGIC/
CONTROL
CIRCUIT

THERMOSTAT
LOGIC
CIRCUIT

POWER
SUPPLY

6

7

7

6

AUX. HEAT
LED (GRN)

HEAT 3