13) Make sure the control switch is in the “OFF” position. Plug the appliance into the

electrical outlet.

14) Move the control switch to the “ICE” position.

15) Replace the air fi lter in its correct position.

16) To confi rm bin control operation, press the bin control’s actuator paddle during the fi rst

5 minutes of the freeze cycle. The compressor, fan motor (if applicable), and pump
motor should de-energize within 15 seconds, then the drain valve should energize
until the water tank empties. After the water tank empties, the drain valve should de-
energize.

17) Close the door.

III. Cleaning and Maintenance Instructions

WARNING

CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are
securely in place after any cleaning or maintenance is done to the unit. Make sure that
none have fallen into the storage bin.

A. Cleaning

HOSHIZAKI recommends cleaning this unit at least once a year. More frequent cleaning,
however, may be required in some existing water conditions.

WARNING

• To prevent injury to individuals and damage to the icemaker, do not use ammonia

type cleaners.

• Carefully follow any instructions provided with the bottles of cleaning and sanitizing

solution.

• Always wear liquid-proof gloves to prevent the cleaning and sanitizing solutions from

coming into contact with skin.

NOTICE

To prevent damage to the water pump, do not leave the control switch in the “WASH”
position for extended periods of time when the water tank is empty.