Interfaces

Interfaces

Interfaces

Interfaces
I/O Chip

SMSC LPC47B397 Super I/O

SMSC LPC47B397 Super I/O

Serial Port / UART Type

One Serial Port

One Serial Port

Parallel Port

One Parallel Port

One Parallel Port

USB

8 USB 2.0 ports (6 rear/2 front)

8 USB 2.0 ports (6 rear/2 front)

Infrared Port

No

No

Network

RJ-45

RJ-45

Keyboard

Yes (PS2 and USB)

Yes (PS2 and USB)

Mouse

Yes (PS2 and USB)

Yes (PS2 and USB)

Multibay

No

No

Video (VGA/DVI-D)

Yes/Yes

Yes/Yes

Audio

Yes

Yes

Unit Environment and

Unit Environment and

Unit Environment and

Unit Environment and
Operating Conditions

Operating Conditions

Operating Conditions

Operating Conditions

Microtower

Microtower

Microtower

Microtower

Small Form Factor

Small Form Factor

Small Form Factor

Small Form Factor

General Unit Operating Guidelines

Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.

Power Supply

Power Supply

Power Supply

Power Supply
Power Supply

250-watt ATX power supply - PFC
115v/230v line switch

200-watt ATX power supply - PFC
115v/230v line switch

Full Ranging Input (No Line Select Switch)

No

No

Active Power Factor Correction (APFC)
(Input Current is nearly 1/2 a non-APFC PS)

No

No

Passive Power Factor Correction (PFC)

Yes (with line switch set to 230V - No PFC
in 115V line switch position)

Yes (with line switch set to 230V - No PFC
in 115V line switch position)

Operating Voltage Range

90 to 132VAC, or 180 to 264VAC

90 to 132VAC, or 180 to 264VAC

Rated Voltage Range

100 to 127VAC, or 200 to 240VAC

100 to 127VAC, or 200 to 240VAC

Rated Line Frequency

50-60 Hz

50-60 Hz

Operating Line Frequency Range

47-63 Hz

47-63 Hz

Rated Input Current

5A @ 100VAC/2.5A @ 200VAC

6A @ 115VAC/23.0A @ 230VAC

Maximum Rated Power

250 watt

200 watt

Heat Dissipation

Maximum 1260 BTU/hr, 317 kg-cal/hr
Typical 256 BTU/hr, 65kg-cal/hr

Maximum 971 BTU/hr, 245kg-cal/hr,
Typical 256 BTU/hr , 65kg-cal/hr

PS Fan

Variable speed fan

Variable speed fan

Processor Fan

Variable speed fan

Variable speed fan

QuickSpecs

HP dx5150 Business PC

HP dx5150 Business PC

HP dx5150 Business PC

HP dx5150 Business PC

Standard Features – Base Unit Details

DA - 12105 Worldwide — Version 7 — August 23, 2005