T8611g chronotherm, Iv deluxe programmable heat pump thermostats – Honeywell Chronotherm IV T8611G User Manual
Page 2
69-0936—1
2
T8611G CHRONOTHERM
®
IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS
W2
L1
(HOT)
L2
M11311
FAN
RELAY
Y1
G
E
THERMOSTAT
C
HEAT
RELAY
1
R
W1
COMPRESSOR
CONTACTOR
EM. HT.
RELAY
TRANSFORMER
HEAT
RELAY
2
OT
OT
OUTDOOR
SENSOR
COOLING OR
HEATING
CHANGEOVER
VALVE
O/B
X2 L
X1
EQUIPMENT
MONITOR 2
EQUIPMENT
MONITOR 1
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
EM. HT. RELAY DOES NOT CYCLE. TO TURN OFF THE EM. HT.,
SET SYSTEM SELECTION TO HEAT.
2
1
2
WIRES
THROUGH WALL
WALL
MOUNTING
HOLES
M15044
MOUNTING
SCREWS
WALL
ANCHORS
(2)
Fig. 1. Typical location of thermostat.
Fig. 3. Typical hookup of T8611G
in a heat pump system.
5 FEET
[1.5 METERS]
YES
NO
NO
NO
M10106
Fig. 2. Mounting the wallplate.
IMPORTANT
Use 18 gauge, color-coded thermostat cable for
proper wiring.
2. Securely tighten each terminal screw.
3. Push excess wire back into the hole.
4. Plug the hole with nonflammable insulation to
prevent drafts from affecting the thermostat.