beautypg.com

Honeywell CT1801 User Manual

Page 19

background image

19

69-0395—2

Troubleshooting

(continued)

1 Not applicable on heating-only model.

1

(continued)

Problem

Check

Action

No heat (continued).

— other.

Contact a qualified service technician for
assistance.

Energy savings
temperature program 12
hours off.

— program dial for proper day or

night phase.

Turn clock ahead 12 hours Move minute
hand clockwise only.

Rooms do not warm up
at programmed time.

— clock program for heating system.

May need more time to warm up
rooms.

Move red pin one-half hour earlier on the
program dial.

Temperature change
occurs at the wrong
time.

— program pins for correct time

locations.

Relocate pins to desired settings.

Room temperatures are
not correct.

— positions of thermostat setpoint

levers.

Reset to desired temperatures.

— position of subbase system

switch.

Move to desired operating position.