beautypg.com

Accessories, Warning – Hearth and Home Technologies CASTLEWOOD 42 User Manual

Page 21

background image

Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev D • 11/11

21

8

Accessories

Figure 8.1 Gas Line Installation

A. Gas Log/Lighter Provisions

A certified gas log lighter or decorative gas log set can be

installed in this fireplace.
This fireplace was not tested and listed for use with an un-

vented gas log heater. Do not install an unvented gas log

heater in this fireplace and operate it with the flue damper in

the closed position unless the unvented gas log heater has

been specifically tested and listed for use in this fireplace by

Underwriters Laboratories Inc.
Use of an unvented gas log heater in this factory built

fireplace may create a fire hazard that can result in a

structure fire.
• Maximum input is 100,000 BTU/hr.

• Decorative gas appliance must be certified to

ANSI Z21.60

“Standard for Decorative Gas Appliances for Installation

in Vented Fireplaces”.

• Must be installed in accordance with the

National Fuel

Gas Code, ANSI Z223.1.

• A log set must incorporate a gas shutoff.

• Log set requires the damper to be locked fully open.

• A locating dimple is on both sides of the hearth refractory.

Determine if a gas line is necessary and drill with a 1” in.

masonry bit. Drill parallel with the back of the fireplace.

• We recommend you seal refractory around pipe with

fireplace mortar or high temperature, noncombustible

sealant.

• Repack insulation from the knockout around the pipe.

• Maintain 1-1/2 in. (38 mm) air space around the pipe for

4 in. (102 mm) beyond the fireplace.

• See Figure 8.1.

Asphyxiation Risk

• Damper must be locked open when gas logs

installed.

Gas fire generates fumes.

WARNING

Fire Risk

• For use with solid wood fuel or decorative

gas appliance only.

• DO NOT install unvented gas logs.

WARNING

Fire Risk

Explosion Risk

Inspect appliance and components for

damage. Damaged parts may impair safe

operation.

• Do NOT install damaged components.

• Do NOT install incomplete components.

• Do NOT install substitute components
Report damaged parts to dealer.

WARNING

Firebox

Repack

insulation

knockout

Combustible

materials

Maintain air clearance

to combustibles.

Gas line

Combustible materials

may be located at zero

clearance to gas line

beyond 4 in. (102 mm)

from fireplace side.

Gas line

1 1/2 in. (38 mm)

air space around

pipe

Refractory

Seal with

fireplace mortar

or non-combust-

ible sealant

4 in.

(102 mm)

Outer shell